eMMC Pro V1.06 [19 AUG 2016] Description :
eMMC Pro V1.06 Release Notes
Error Messages and Handling ; Code: CMD_CRC_FAIL = (1) which is Command response received (but CRC check failed) DATA_CRC_FAIL = (2) which is Data bock sent/received (CRC check Failed) CMD_RSP_TIMEOUT = (3) which is Command response timeout DATA_TIMEOUT = (4) which is Data time out TX_UNDERRUN = (5) which is Transmit FIFO under-run RX_OVERRUN = (6) which is Receive FIFO over-run START_BIT_ERR = (7) which is Start bit not detected on all data signals in widE bus mode CMD_OUT_OF_RANGE = (8) which is CMD's argument was out of range ADDR_MISALIGNED = (9) which is Misaligned address BLOCK_LEN_ERR = (10) which is Transferred block length is not allowed for the card or the number of transferred bytes does not match the block length ERASE_SEQ_ERR = (11) which is An error in the sequence of erase command occurs BAD_ERASE_PARAM = (12) which is An Invalid selection for erase groups WRITE_PROT_VIOLATION = (13) which is Attempt to program a write protect block LOCK_UNLOCK_FAILED = (14) which is Sequence or password error has been detected in unlock command or if there was an attempt to access a locked card COM_CRC_FAILED = (15) which is CRC check of the previous command failed ILLEGAL_CMD = (16) which is Command is not legal for the card state CARD_ECC_FAILED = (17) which is Card internal ECC was applied but failed to correct the data CC_ERROR = (18) which is Internal card controller error GENERAL_UNKNOWN_ERROR = (19) which is General or Unknown error STREAM_READ_UNDERRUN = (20) which is The card could not sustain data transfer in stream read operation. STREAM_WRITE_OVERRUN = (21) which is The card could not sustain data programming in stream mode CID_CSD_OVERWRITE = (22) which is CID/CSD overwrite error WP_ERASE_SKIP = (23) which is only partial address space was erased CARD_ECC_DISABLED = (24) which is Command has been executed without using internal ECC ERASE_RESET = (25) which is Erase sequence was cleared before executing because an out of erase sequence command was received AKE_SEQ_ERROR = (26) which is Error in sequence of authentication. INVALID_VOLTRANGE = (27) ADDR_OUT_OF_RANGE = (28) SWITCH_ERROR = (29) SDIO_DISABLED = (30) SDIO_FUNCTION_BUSY = (31) SDIO_FUNCTION_FAILED = (32) SDIO_UNKNOWN_FUNCTION = (33) Standard errors and messages ; Code: INTERNAL_ERROR = (34) NOT_CONFIGURED = (35) REQUEST_PENDING = (36) REQUEST_NOT_APPLICABLE = (37) INVALID_PARAMETER = (38) UNSUPPORTED_FEATURE = (39) UNSUPPORTED_HW = (40) ERROR = (41) OK = (42) CMD1_TIMEOUT = (60) Advanced eMMC Repair eMMC PRo - Universal Device Programmer
|